Sil fos 15 datasheet pdf

Best alloy for general purpose coppercopper brazing in the sil fos family. Vishay, disclaim any and all liability fo r any errors, inaccuracies or incompleteness contained in any datasheet or in any o ther disclosure relating to any product. Sil fos 15 is a copper rich, filler metal that is selffluxing on copper by virtue of its phosphorus content. Please call for pricing and availability or fill out the application data sheet pdf and quote request form. Q2 pchannel 0 2 4 6 8 10 0 2 4 6 8 10 q g, gate charge ncv gs, gatesource voltage v i d 5a v ds 5v 10v. Silfos5 silver copper phosphorus brazing filler metal.

The sil fos alloys vary in silver content from 18% to 2% and the percentage of silver and phosphorous does change the melt and flow characteristics of the filler metal. Short term exposure limit 15 minute twa value constituents and decomposition products. Easyflo alloys are freeflowing filler metals that have been the standard in the industry for over 60 years. Other companies are charging thousands of dollars to set up accounts and give you access to their msds online database.

Sil fos 5 is a 5% silvercopperphosphorus brazing filler metal, which is used to braze copper and copper alloys. For use where close fitups cannot be maintained sil fos 15 works well to bridge gaps. The self fluxing property of this filler metals is effective on copper only. Silfos 15 and was developed primarily for use on copper, but its use has extended to other. Ground the aircraft and the application equipment before top coating. For coppertocopper joints the phosphorus in the sil fos product serves as the fluxing agent and no seperate flux is necessary. The percentage is the percentage of silver content in the rod. When sil fos 5 is used to join copper alloys such as brass, bronze or gun metal a separate flux will be required. The silfos 15 is the best alloy for general coppercopper brazing in the silfos family. From 1050 ppm w to 60 ppm w in accordance with ari 71086. Best alloy for general purpose coppercopper brazing in the silfos family. Stay silv 15 brazing filler metal is a frequent choice for brazing copper, especially in.

The lfx98x devices are monolithic sampleandhold circuits that use bifet technology to obtain ultrahigh dc accuracy with fast acquisition of signal and low droop rate. Consequently it is used to manufacture a wide range brazing filler metal preforms, rings and punched or pressed parts such as discs, washers and clips. Your new online msds binder is a place for you to store the material safety data sheets you need to deploy. Technical data sheet december 2016 fos flo page 2 of 2 lucasmilhaupt, inc. Sil fos and sil fos 5 should not be used on nickelbase alloys, as the phosphorus reacts with the nickel or iron to form brittle compounds at the interface of the joints.

Harris staysilv 15 15 % silver brazing rod 15620f1 is sold as a one pound tube with approximately 28 sticks. Silfos is the most ductile of this range silfos 6 has the best flow of the group but has less alloy ductility. Recent listings manufacturer directory get instant. On brass, bronze and other copper alloys a separate flux is needed. The silfos alloys vary in silver content from 18% to 2% and the percentage of silver and phosphorous does change the melt and flow characteristics of the filler metal.

Joints should not be exposed to sulphur containing. Sil fos 5, because of its higher phosphorus content, is more fluid than sil fos 15 when heated rapidly to its flow point. C8051f330 and c8051f331 and c8051f332 and c8051f333. Instructions for brazing fittings to pipe and tubing with braze, easyflo and sil fos lowtemperature silver alloy brazing with braze, easyflo or sil fos i s extensively used for joining pipe and tubing. Silicon image confidential for research institute of electronic technology internal use only sii 95 hdmi receiver data sheet silicon image, inc.

Instructions for brazing fittings to pipe and tubing with braze, easyflo and silfos lowtemperature silver alloy brazing with braze, easyflo or silfos i s extensively used for joining pipe and tubing. Due to its ductility sil fos is the only filler metal of its type that can be fabricated into foil, tape, strip and fine wire. Si482536a antenna, schematic, layout, and design guidelines. These alloys have been used successfully on nearly all. Safety data sheet according to federal register vol. We have several search tools, listed above, that give you more efficient methods to reach the information that you need. This page has links to all data sheets in matweb for the tradename silfos. For fire, the detector combines four separate sensing elements in one unit smoke, co, lightflame, and heat to sense multiple components of a fire.

This page has links to all data sheets in matweb for the tradename sil fos. When brazing copper the phosphorus within the alloy imparts a metallurgical based selffluxing capability. Both silfos and silfos 5 are mutually soluble with copper and copper alloy base metals. Silicon labs c8051f330, c8051f331, c8051f332, c8051f333. Sil fos 15 safety data sheet according to federal register vol. Silicon image confidential for research institute of electronic technology internal use only sii 95 hdmi receiver. Choosing the proper filler metal is a must in order to provide a quality connection between two metals. Baytec sil 70 page 1 of 5 document contains important information and must be read in its entirety. Woking unit 19, woking business park, albert drive, woking, gu21 5jy tel. Sil datasheet, sil pdf, sil data sheet, sil manual, sil pdf, sil, datenblatt, electronics sil, alldatasheet, free, datasheet, datasheets, data sheet, datas sheets. To ensure proper operation and receiver performance, follow the guidelines in an738. This item lucasmilhaupt 98703 sil fos 15 58 brazing rings weldingcity 5pcs copper phosphorus filler brazing rod silver 15 % bcup5 20 x 18 x 0.

Not to be used on ferrous or nickel based parent metals. Lucas milhaupt safety data sheets sds provide explicit instructions for operators to ensure a safe and effective application. Material safety data sheet pdf additional information. Us federal regulations silver 7440224 listed on the united states tsca toxic substances control act inventory subject to reporting requirements of united states sara section 3 cercla rq lb no reporting of releases of this hazardous substance is required if the diameter of the.

Jan 26, 2020 the most common rods used for typical hvac brazing are 0%, 5% and 15 % with several other levels mixed in there. Due to its ductility silfos is the only filler metal of its type that can be fabricated into foil, tape, strip and fine wire. It can be readily bent without heating, thus permitting easier access to the backsides of joints. Cas 7440508 7723140 7440224 sil fos 15 71150, silvercopper supdat copper sara 3 cercla phosphorous red. For brass application however, flux is recommended.

Silfos and silfos 5 should not be used on nickelbase alloys, as the phosphorus reacts with the nickel or iron to form brittle compounds at the interface of the joints. With copperbase alloys, such as brass or bronze, the joints should be fluxed with handy flux. Lucasmilhaupt believes the information contained herein to be reliable. Both sil fos and sil fos 5 are mutually soluble with copper and copper alloy base metals. Lucas milhaupt technical data sheets tds provide additional information on each alloy and its characteristics, physical properties, and nominal composition. Matweb material list by tradename this page has links to all tradenames in matweb starting with the letter a. Ca82x4 1 hour 30 minutes 15 minutes application guidelines recommended application conditions. Skfireco advanced combination fire and co detector the skfireco is a plugin, addressable device that provides both fire and carbon monoxide co detection. The only real reason to use lower silver levels is the cost and the difference can have many techs and owners wondering what the difference is. Accidental release measures methods and materials if a finelydivided form of product is spilled, clean up spillage so as to. Manufacturer information manufacturersupplier harris products group 4501. Wear suitable protective clothing, gloves and eye face protection during brazing. The most common rods used for typical hvac brazing are 0%, 5% and 15% with several other levels mixed in there.

Silfos 15 15 percent silver brazing rod the macomb. Safety data sheets sds include information on product ingredients, physical and chemical properties, potential effects on toxicology and ecology, identification of hazards, handling and storage instructions, as well as personnel protection recommendations and information related to transportation requirements, firstaid and emergency processes. Silfos is the workhorse filler metal used in the ac and refrigeration industry. They are versatile, highstrength alloys that have the lowest melting point of all silver based brazing materials. C8051f330 and c8051f331 and c8051f332 and c8051f333 and. Njl5161k datasheet, cross reference, circuit and application notes in pdf format.

Sil fos 15 or sil fos 5 may be preferred, particularly if the joints are to be subjected to impact or vibration in service. Edition 20140529 replaces edition dated 20120815 product datasheet characterization baytec sil 70 coating is a single component silicone material. Find nickel silver sheet related suppliers, manufacturers, products and specifications on globalspec a trusted source of nickel silver sheet information. The corrosion resistance of fosflo 7 is comparable to that of copper except when exposed to sulfur compounds and sulfurcontaining gas or oil, especially at elevated temperatures. Cas 7440508 7723140 7440224 silfos 15 71150, silvercopper supdat copper sara 3 cercla phosphorous red.

Silfos5 is a 5% silvercopperphosphorus brazing filler metal, which is used to braze copper and copper alloys. For use where close fitups cannot be maintained silfos 15 works well to bridge gaps. Lucasmilhaupt sil fos is for use where close fitups cannot be maintained and joint ductility is important. Silicon image confidential for research institute of electronic technology internal use only data sheet. Body diode forward voltage variation with source current and temperature.

When silfos5 is used to join copper alloys such as brass, bronze or gun metal a separate flux will be required. Silf330 datasheet, silf330 pdf, silf330 data sheet, silf330 manual, silf330 pdf, silf330, datenblatt, electronics silf330, alldatasheet, free, datasheet, datasheets. It is the only phoscopper silver filler metal available in strip or sheet form. Instructions for brazing fittings to pipe and tubing with. Pchannel 40 v d s mosfet features halogenfree according to iec 61249221 definition tefhcne tr power mosfet 100 % rg tested compliant to rohs directive 200295ec applications load switch dcdc converter notes.

Silvercopperphosphorus brazing alloys safety data sheet. Sil fos 5 has less tendency to form large fillets or to fill poorly fitted joints compared to sil fos 15. Operating as a unitygain follower, dc gain accuracy is 0. The applicable lucasmilhaupt product codes for this technical data sheet. Some sil fos alloys are available in strip as well. Technical data sheet january 2014 silfos 15 page 2 of 4 lucasmilhaupt, inc. Alloys for brazing and other metallurgical processes 2.

It makes assemblies that are strong, permanently leaktight and maintenancefree, and is an extremely simple, lowcost process. An economical, very fluid medium temperature filler metal for use with copper, brass and bronze. Silfos 15 is the best alloy to use when joining metals where close fitups cannot be maintained and is well suited for use in referigeration applications. Silfos silver copper phosphorus brazing filler metal. Lucasmilhaupt silfos is for use where close fitups cannot be maintained and joint ductility is important. Lucasmilhaupt 95150 silfos 15 brazing alloy 28 rod tube. Q1 nchannel 0 2 4 6 8 10 0 2 4 6 8 10 12 q g, gate charge nc v gs, gatesource voltage v i d 7a v ds 10v 15v 20v 200 400 600 800 0 5 10 15 20. Sil fos 15 should not be used on nickelbase and ironbase. For flux free brazing of copper or high copper content alloys. Hvacr refrigerant systems, air conditioning coils, evaporator coils. This item lucasmilhaupt 95150 sil fos 15 brazing alloy 28 rod tube forney 48571 super sil flo brazing rod, 18inch, 12pound supplying demand 15 % silver solder brazing rods 4 19. Technical data sheet january 2014 sil fos 15 page 2 of 4 lucasmilhaupt, inc.

1237 1518 1199 364 1009 1069 173 287 865 1253 265 44 163 204 502 1299 1370 1164 1430 482 1394 1404 457 1155 273 544 4 1177 793 503 1055 16 1237 727 160 546 906 1162 1323